15/05/2026
With an annual production capacity of 3 million power meters!
Acrel's automated flexible production workshop integrates SMT assembly, electronic assembly, and complete machine testing.
The entire process is intelligently linked with precise robotic arm operations, and the information system manages the entire process.
Acrel is ISO9001+CNAS certified, and every meter is meticulously manufactured!
METER monitoring
12/05/2026
The orientation of the Current Transformer (CT) is crucial for accurate readings and proper protection.
You'll usually find markings on the CT body like:
P1/P2 or K/L. On the secondary: S1/S2. The common rule is:
P1 or K → Source side
P2 or L → Load side. This means current enters at P1 and exits at P2.
Example: If you have a panel:
Power is coming from the main breaker to the motor or load,
then:
P1 should be pointed towards the breaker/source, and P2 towards the load.
What if it's connected backward?
The current might read negative in some devices. The power and power factor might be affected. Directional protection might trip incorrectly. Some meters might register in reverse. Very important note: Never leave the secondary of the CT open while it's operating. It must be:
Connected to a meter/relay or Short-circuited.
If need CTs,please contact:
Email:[email protected]
Whatsapp:+86-13482177205
voltage transformer
21/04/2026
Join us at Hannover Messe with Acrel!
Let’s connect, explore opportunities & meet at the show.
Booth: Hall 13, G59
Time: 20-24th, April, 2026
Feel free to reach out!
20/04/2026
Acrel medical isolation power monitoring system is used to monitor medical class 2 places (operating room, lCU.CCU) to provide safe, reliable and continuous power distribution for these important places. At the same time, assistthe O&M personnel to find and eliminate insulation faults in time to further improve the reliability of the system.
For more details, you can contact:
Email:[email protected]
Whatsapp:+86-13482177205
safety for ICU&CCU
07/04/2026
Acrel Telecom Base Station energy meter could help monitor the electrical parameters of AC and DC distribution system of Telcom base station in real time.provide online monitoring and energy consumption analysis of operation status, improve the efficiency of basestation operation and maintenance control, and reduce the operation cost.
27/03/2026
Wireless Three Phase Energy Meter
Measurement:U、I、 P、Q、S、PF、F、THDv、Harmonic on 2nd-31st,etc
Wireless Communication: 4G,WIFI,LoRawan(US915,EU868,EU923)
Protocol:MQTT,Modbus-Rtu,Modbus-TCP
Accuracy:0.5S Class
Extra function:Max 4 loops temperature measurement
Extra function:Work with Rogowski coil
For more details,please contact:
Whatsapp:+86-13482177205
Email:[email protected]
23/03/2026
Acrel microgrid energy management system, Acrel-2000MG, accommodates the integration of photovoltaic systems, energy storage systems,charging piles, diesel generators, user loads, and other equipment, peforming around-the-clock data collection and analysis. It monitors the operational status and health of photovoltaic, energy storage, diesel generator, load and other systems,serving as a comprehensive management system that integrates monitoring and energy management, This system aims foreconomic optimization based on safety and stability, promoting the utilization of renewable energy, peak shaving, load leveling improving grid operational stability and equipment operational eficiency, and reducing power supply costs, it provides a new solution for the safe, reliable, and economical operation of enterprise microgrids.
Acrel2000-MG Microgrid Energy Management System-Solutions-Acrel Co.,Ltd.
System Introduction Acrel microgrid energy management system, Acrel-2000MG, accommodates the integration of photovoltaic systems, energy storagesystems,charging piles, diesel generators, user loads, and other equipment, peforming around-the-clock...
16/03/2026
Wireless temperature is suitable for 3~35kV indoor switchgears, including built-in switchgears, handcart
switchgears, fixed switchgears and loop-net switchgears. It is also suitable for 0.4kV low-voltage switchgears
such as fixed switchgears and drawer switchgears. The wireless temperature sensors can be installed at any
heating point in switchgears, the device utilizes the wireless data transmission technology for real-time
transmission of monitored temperature data. In addition, it can be transmitted to display device or remote
intelligent monitoring system.
For more details,also could contact follow contact:
Email:[email protected]
Whatsapp:+86-134 82177205
20/06/2025
📡 AMC16L-DETT Multi-circuit DC Meter – Comprehensive Energy Management Solution for Telecom Base Stations
AMC16L-DETT + Hall Sensors + IoT Gateway + Acrel Cloud Platform
·🔍 Multi-Circuit Monitoring: Measures up to 6 DC channels with high accuracy
·📊 Shared Metering: Tracks power usage by multiple operators for better energy optimization
·⚠️ Smart Alarms: Instant alerts for DC over/under-voltage, ensuring system safety
🤝 Our trusted partners include American Tower, Helios Towers, EdgePoint, IHS etc.
📲 Ready to upgrade your tower station energy management system? Contact us now.