Panasonic Air Conditioner Troubleshooting
The following symptoms do not indicate malfunction;
Symptom: Mist emerges from indoor unit.
Cause: Condensation effect due to cooling process
Symptom: Water fl owing sound during operation.
Cause: Refrigerant fl ow inside the unit.
Symptom: The room has a peculiar odour
Cause: This may be due to damp smell emitted by the wall, carpet, furniture or clothing
Symptom: Indoor fan stops occasionally during automatic fan speed setting.
Cause: This helps to remove the surrounding odour
Symptom: Airflow continues even after operation has stopped
Cause: Extraction of remaining heat from the indoor unit (maximum 30 seconds).
Symptom: Operation is delayed a few minutes after restarting
Cause: The delay is a protection to the unit’s compressor.
Symptom: Outdoor unit emits water/steam
Cause: Condensation or evaporation occurs on pipes
Symptom: POWER indicator blinks during HEAT mode with no warm air supply (and louver is closed)
Cause: The unit is in defrost mode (and AIR SWING is set to AUTO).
Symptom: Indoor fan stops occasionally during heating operation.
Cause: To avoid unintended cooling effect
Symptom: POWER indicator blinks before the unit is switched on.
Cause: This is a preliminary step in preparation for the operation when the ON timer has been set
Symptom: Cracking sound during operation
Cause: Changes of temperature caused the expansion/contraction of the unit
Symptom: POWER indicator blinks 3 seconds ON and 0.5 seconds OFF during operation
Cause: The unit is in Demand Response Mode
Check: the following before calling for servicing
Symptom: Operation in HEAT/COOL mode is not working efficiently
Check:
Set the temperature correctly.
Close all doors and windows.
Clean or replace the fi lters.
Clear any obstruction at the air inlet and air outlet vents
Symptom: Noisy during operation
Check:
Check if the unit has been installed at an incline
Close the front panel properly
Symptom: Remote control does not work
Check:
Insert the batteries correctly
Replace weak batteries
Symptom: The unit does not work
Check:
Check if the circuit breaker is tripped.
Check if timers have been set
Symptom: The unit does not receive the signal from the remote control.
Check:
Make sure the receiver is not obstructed.
Certain fl uorescent lights may interfere with signal transmitter. Please consult authorised dealer
21/11/2019
Penyambungan cooper pipe (saki baki).tuan rumah nak macam tu.save budget.(barang tuan rumah:cooper pipe)
Service aircond (buka dan cuci)
18/11/2019
Service (buka dan cuci) aircond 1.5 hp .Taman bertam impian melaka
05/10/2019
Service #
Wyring and aircond installation new
29/09/2019
Kota laksamana..Full wyring replace old wyring and install new aircond 8 split unit..01136113154.pashini..Melaka
Click here to claim your Sponsored Listing.
Location
Contact the business
Telephone
Website
Address
Johor Bahru